Information

technical requirements

2.1 physicochemical indexes

2.1.1 

Bleach in use should be white, powder form, effective chlorine content should be > 20%.

2.1.2

Bleaching powder in use should be white or slightly gray, powder, effective chlorine content should be > 55%.

2.1.3

The tablet weight error rate should be < 5.0%;

Effervescent tablets should be labeled with disintegration time, which should be < 5.0min.

2.1.4

For disinfection of tableware, fruits and vegetables, the content of heavy metal (in terms of lead) shall be ≤30mg/kg, and the content of arsenic shall be ≤3.0mg/kg.

2.2 stability

The degradation rate of the effective chlorine content of the bleaching powder (tablet) within 6 months shall be less than 15%, and the fluctuation of the mark range of the effective chlorine content of the product shall be less than 15%.

The degradation rate of the effective chlorine content in bleaching powder (tablet) within 12 months should be < 10%, and the fluctuation of the mark range of the effective chlorine content of the product should be < 10%.

The effective chlorine content within the effective period of the product shall not be lower than the lower limit of the mark range.

2.3 disinfection effect

The requirements in table 1 should be met.

Table 1    

Bleaching powder, bleaching powder fine disinfectant disinfection effect test requirements

 

Microbial class

Effective chlorine content

mg/L

action timemin

Killing pair

escherichia coli

8099*

100

10

≥5.0

Staphylococcus aureus

ATCC6538*

200

10

≥5.0

Pseudomonas aeruginosaATCC15442*

200

10

≥5.0

Candida albicans

ATCC10231*

200

10

≥4.0

Polio virus - Ⅰ vaccine strains*

200

20

≥4.0

spores of bacillus subtilis var nigerATCC9372

5000

60

≥5.0

 

(1)*The concentration of the interfering organic substance used in the killing test is 0.3%.

(2)Testing requirements for product hygiene and safety evaluation: quantitative killing test of staphylococcus aureus for disinfection of surfaces and fabrics;

Quantitative killing test of escherichia coli for disinfection of drinking water, fruits and vegetables;

Poliovirus inactivation test for disinfection of food and drink utensils;

Quantitative killing test of bacterial spores for disinfection of humoral contaminated articles, sewage and excreta.

Keyword:

Releate News

What are the applications of biological treatment in wastewater treatment engineering?
What are the applications of biological treatment in wastewater treatment engineering?
There are two types of biological treatment technologies that are most widely used in wastewater treatment projects: one is called activated sludge method, and the other is called biofilm method. The activated sludge process is a form of aerobic wastewater treatment performed by the biochemical metabolism of suspended biological groups.
See more information
There are two types of biological treatment technologies that are most widely used in wastewater treatment projects: one is called activated sludge method, and the other is called biofilm method. The activated sludge process is a form of aerobic wastewater treatment performed by the biochemical metabolism of suspended biological groups.
Swimming pool water treatment should pay attention to four matters
Swimming pool water treatment should pay attention to four matters
1、The residual chlorine content should not be too high to ensure that the free residual chlorine in the swimming pool water is controlled between 0.3 and 1.0 mg/L, and the combined residual chlorine is controlled within the range of <0.4 mg/L.....
See more information
1、The residual chlorine content should not be too high to ensure that the free residual chlorine in the swimming pool water is controlled between 0.3 and 1.0 mg/L, and the combined residual chlorine is controlled within the range of <0.4 mg/L.....
How to choose water treatment application equipment?
How to choose water treatment application equipment?
Standard 1: look at qualifications. The Health Supervision Center of the Ministry of Health of the People's Republic of China has clearly issued: Measures for the Supervision and Administration of Drinking Water Sanitation, in which Article 21 clearly states: Therefore, all products without a health permit issued by the Ministry of Health are classified as "unlicensed driving". not protected by law.
See more information
Standard 1: look at qualifications. The Health Supervision Center of the Ministry of Health of the People's Republic of China has clearly issued: Measures for the Supervision and Administration of Drinking Water Sanitation, in which Article 21 clearly states: Therefore, all products without a health permit issued by the Ministry of Health are classified as "unlicensed driving". not protected by law.
Previous page